What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE MAIN LEFT WHEEL WELL STRINGER 18A SHEAR BEAM CRACKED AT BS 706. REMOVED FASTENERS TO GAIN ACCESS, STOPPED DRILL CRACKED, INSTALLED KIT (P/N 65C29228-15) IAW SB 737-53-1066 AND RES NR 99439.