What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND ON THE AFT PIT WEB AT BS 965 TO 985 STRINGER 28-29R CORRODED ON BOTH SIDES. FABRICATED NEW INTERCOSTAL WEB, HEAT TREATED, PRIMED, AND INSTALLED REPAIR IAW DC9 SRM 51-10-2A, 51-10-5, 51-30-8, 53-03 FIG 1, 51-30-2, AND 51-30-5.