What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE L-1 DOOR STRIKING BEHIND MOUNT U-CHANNEL ANGLE ON AFT DOOR JAMB AT UPPER STOP BOLT. BLENDED OUT DAMAGE AREA TO HAVE MINIMUM RADIUS, TREATED TRIMMED AREA, PRIMED AND DRESSED UP IAW DC9 53-01-0, 53-11-0, AND RES NR 99452.