What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE LEFT HAND FLOOR WEB AT BS 617 CRACKED. FORMED DOUBLERS, DRILLED, DEBURRED, TREATED, PRIMED, AND INSTALLED REPAIR AND REINSTALLED TWO PREVIOUSLY REMOVED BAFFLES IAW DC9 SRM 51-10-4, 53-20-1, 51-10-3, 51-30-2, AND RES NR 99358.