What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE VERTICAL STABILIZER LEFT HAND UPPER PANEL 3703A SKIN CHAFED. BLENDED OUT CHAFE ON LEFT HAND VERTICAL STABILIZER SKIN, TREATED, PRIMED IAW DC9 SRM 55-01-0, 55-32-0, 55-01-0, 51-10-3, AND RES NR 99573.