What was found
SCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE RIGHT SIDE NR 1 SLAT LOWER EXTERNAL SURFACE DENTED JUST INBOARD OF ANTI-ICE DUCT. CUT INNER SKIN FOR ACCESS, FABRICATED DOUBLER AND SKIN SPLICE DOUBLER, DRILLED, COUNTERSUNK, TREAT, PRIMED, AND INSTALLED IAW DC9 SRM 51-10-3, 57-09 FIG 10 AND 10A, 51-30-2, 51-30-8, AND RES NR 99603.