What was found
SCHEDULED INSPECTION AT AERO CORP, FL, FOUND CORROSION ON FLOOR AT BS 965 LBL-50 JUST AFT OF WALL. REMOVED CORROSION, FABRICATED NEW DOUBLER, DRILLED, DEBURRED, TREATED, PRIMED, AND INSTALLED IAW DC9 SRM 51-10-3, 53-01 FIG 1, 51-10-4, 53-20-1, AND 51-30-2.