What was found
SCHEDULED INSPECTION AT AERO CORP, FL, FOUND IN THE AFT GALLEY WORK AREA UNDER THE COFFEE AND SNACK DOOR AN ANGLE CORRODED. REMOVED ANGLES FOR ACCESS, FABRICATED NEW REPAIR U CHANNEL, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED TWO EACH ANGLES AND U CHANNEL IAW DC9 SRM 51-10-2, 51-10-3, 51-10-4, 51-30-2, 51-30-5 AND 53-01 FIG 1.