What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE FORWARD FLOOR PANEL NR 4691 AT BS 160 TO 200 BL 0-45L CORRODED. FABRICATED NEW FLOOR PANEL, FIT, DRILLED AND INSTALLED NEW SKIN ON HAT CHANNELS AND REINSTALLED FLOOR PANEL IAW DC9 SRM 53-21-0, 51-10-2, AND 53-31-0.