What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THREE FLOORBOARD SUPPORT BRACKETS AT BS 160 TO 218 LBL 1 TO 55 CORRODED. FABRICATED REPAIR FLOOR SUPPORTS, TREATED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-2, 51-10-3, 51-30-5 AND 51-30-2.