What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND FLOORBOARD SUPPORT BRACKET AT BS 160 RBL 0 TO 52 CORRODED. FABRICATED FLOOR SUPPORT ANGLE, DEBURRED, TREATED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-4, 51-10-3, 51-30-2 AND 51-30-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND FLOORBOARD SUPPORT BRACKET AT BS 160 RBL 0 TO 52 CORRODED. FABRICATED FLOOR SUPPORT ANGLE, DEBURRED, TREATED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-4, 51-10-3, 51-30-2 AND 51-30-1.