What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND CUSP ANGLE AT R-1 DOOR JAMB CORRODED AT BS 170 TO 200. FABRICATED REPAIR PARTS, DRILLED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-3, 53-05 FIG 55, 51-30-2 AND 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND CUSP ANGLE AT R-1 DOOR JAMB CORRODED AT BS 170 TO 200. FABRICATED REPAIR PARTS, DRILLED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-3, 53-05 FIG 55, 51-30-2 AND 51-30-5.