What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND A CRACK IN INTERCOSTAL RIGHT HAND FUSELAGE AT BS 148 TO 160 (L10R) FIFTY FOUR INCHES ABOVE CUSP. ROUTED OUT CRACK AND INSTALLED GUSSET AND L ANGLE REPAIR IAW TIMCO EO NR 99-1140.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND A CRACK IN INTERCOSTAL RIGHT HAND FUSELAGE AT BS 148 TO 160 (L10R) FIFTY FOUR INCHES ABOVE CUSP. ROUTED OUT CRACK AND INSTALLED GUSSET AND L ANGLE REPAIR IAW TIMCO EO NR 99-1140.