What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE PASSENGER CABIN FLOORBEAM IN AFT LAVATORY AREA CHAFED AND CORRODED AT BS 980 BL 0-44L. FORMED NEW FLOORBEAM, LOCATED, DRILLED AND DEBURRED. FABRICATED REPAIR DOUBLER, ALODINED, PRIMED AND INSTALLED REPAIR PARTS IAW DC9 SRM 53-05 FIG 79, 51-10-4 AND 51-10-3.