What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND A DENT AT FUSELAGE STATION BS 330 STR 21L. REMOVED EXISTING DOUBLER, TRIMMED OUT DENT, AND FABRICATED A -20 DOUBLER AND -21 TRIPLER. DRILLED, DEBURRED, ALODINED AND INSTALLED REPAIR PARTS IAW B737 51-30-8, 51-20-11, 51-10-2, AND EO 99-1151 SHEET 2 OF 4 STEPS 1-8.