What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND A DENT ON THE FORWARD FUSELAGE AT BS 221.5 (1.5) ABOVE L-18L. FABRICATED TITANIUM FINGER DOUBLER, CUT OUT CREASES, FABRICATED FILLER, DRILLED, DEBURRED, TREATED, PRIMED, AND INSTALLED REPAIR IAW DC9 SRM 53-04-0 AND 51-10-0, 51-30-2 AND RES NR 99-1089.