What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND AN INTERCOASTAL AT BS 1006-1016 LBL-4 CORRODED. REMOVED INTERCOSTAL, FABRICATED REPAIR ANGLE, DRILLED, DEBURRED, TREATED, PRIMED, AND INSTALLED IAW B737 SRM 51-20-11, 51-30-2, 51-10-2, 51-10-6, AND 51-40-3.