What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE FORWARD ENTRY FLOOR PANEL NR 4693 AT LBL 45-65 CORRODED. REMOVED FLOOR PANEL, FABRICATED, COUNTERSUNK, DEBURRED, TREATED, PRIMED, AND INSTALLED IAW DC9 SRM 51-10-3, 51-10-2, 53-21-0 FIG 2D.