What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND ON THE LEFT MAIN CABIN AT BS 928 LONGERON NR 18 ATTACHED WEB CORRODED. MECHANICALLY REMOVED CORROSION, FABRICATED REPAIR DOUBLER AND FILLER, TREATED, PRIMED AND INSTALLED IAW DC9 SRM 53-11-3, 51-10-3 AND 53-20-1.