What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND FRAME IN THE FORWARD PIT AT BS 541 L-29L-29R CORRODED. REMOVED CORROSION, FABRICATED REPAIR PARTS, HEAT TREATED AND INSTALLED IAW DC9 SRM 53-03 FIG 2A, 51-10-4, 51-10-3, AND 51-30-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND FRAME IN THE FORWARD PIT AT BS 541 L-29L-29R CORRODED. REMOVED CORROSION, FABRICATED REPAIR PARTS, HEAT TREATED AND INSTALLED IAW DC9 SRM 53-03 FIG 2A, 51-10-4, 51-10-3, AND 51-30-3.