What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND CORROSION ON LONGERON STRAP AT BS 927 L-23L. FABRICATED REPAIR LONGERON STRAP, ALODINED, PRIMED AND INSTALLED IAW DC9 SRM 53-11-3, 51-10-3 AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND CORROSION ON LONGERON STRAP AT BS 927 L-23L. FABRICATED REPAIR LONGERON STRAP, ALODINED, PRIMED AND INSTALLED IAW DC9 SRM 53-11-3, 51-10-3 AND 51-30-2.