What was found
DURING A SCHEDULED INSPECTION AT TIMCO, IN LAKE CITY, FL, FOUND CRACK BEYOND DOUBLER UNDERSIDE FLOOR SUPPORT FWD CARGO COMPARTMENT AT BS 446 AT LONGERON 30. REMOVED EXISTING SPLICE DOUBLER, STOP DRILLED CRACK, FABRICATED REPAIR AND INSTALLED REPAIR AND SPLICE DOUBLER IAW DC9 SRM 51-30-2, 51-10-3 AND EA NR 12-5321-29-C1362.