What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY, FL, FOUND CRACKED FLOOR SUPPORT FWD CARGO COMPARTMENT AT BS 503 AND BL 3L. STOP DRILLED CRACK IAW EA NR 12-5321-29-C1362 OPT 1 STEP 1. NDT PERFORMED, CRACK CONTAINED. WELD REPAIR 1 EACH CRACK ON FLOOR SUPPORT, TREATED, AND PRIMED IAW DC9 SRM 51-10-3.