What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY, FL, FOUND CRACK IN FLOOR SUPPORT FWD CARGO COMPARTMENT AT BS 522 AND BL 6L. STOP DRILLED, FABRICATED DOULBER REPAIR, TREATED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-3, 53-01 FIG 2, 51-10-4 AND EA NR 12-5321-29-C1362.