What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND END CAP OF BS 598 L-27L CORRODED. REMOVED, RECEIVED NEW END CAP, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-4, 51-10-3, 51-30-2, 51-30-1 AND 53-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND END CAP OF BS 598 L-27L CORRODED. REMOVED, RECEIVED NEW END CAP, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-4, 51-10-3, 51-30-2, 51-30-1 AND 53-01.