What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND CRACKS IN MAIN FRAME AT BS 718L. REMOVED AND REPLACED MAIN FRAME BS 718L IAW AIRTRAN EO 12-5311-29-B1044 FIG 5,6 AND 7.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND CRACKS IN MAIN FRAME AT BS 718L. REMOVED AND REPLACED MAIN FRAME BS 718L IAW AIRTRAN EO 12-5311-29-B1044 FIG 5,6 AND 7.