What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND MAIN FRAME CRACKED AT BS 699L. REMOVED AND REPLACED FRAME IAW AIRTRAN EO 12-5311-29-B1044 FIG 5,6 AND 7.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND MAIN FRAME CRACKED AT BS 699L. REMOVED AND REPLACED FRAME IAW AIRTRAN EO 12-5311-29-B1044 FIG 5,6 AND 7.