What was found
DURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND MAIN RE-FUELING POINT AT LOWER WING SKIN WORN THROUGH WHERE LATCH FOR FUEL DOOR MATES TO LOWER SKIN. FABRICATED FITTINGS. DRILLED, DEBURRED AND COUNTERSUNK HOLES IN FITTINGS. INSTALLED FITTINGS IAW TIMCO EO NR 99-1171, DC9 SRM 57-06B FIG 10, 51-06B SHT 1 AND 2.