What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE AFT PIT TIE DOWN TRACK AT BS 937-996 WITH CORROSION. REMOVED CORROSION, DRILLED, COUNTERSUNK, DEBURRED, TREATED, PRIMED, AND INSTALLED NEW SECTION IAW DC9 SRM 51-10-4, 51-30-1, AND 51-10-3.