SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND CABIN FLOOR SUPPORT AT BS 200-237 LBL-15 CORRODED. REMOVED AND REPLACED FLOOR SUPPORT, DRILLED, TRIMMED, TREATED, PRIMED AND INSTALLED IAW DC9 SRM 51-10-4, 51-30-2, AND 51-10-3.