DURING SCHEDULED CHECK AT TIMCO LAKE CITY FL, FOUND FLOOR PANEL ON RT SIDE AT BS 280 CORRODED. FABRICATED NEW PANEL AND INSTALLED IAW DC9 SRM 51-21-0, 51-30-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED CHECK AT TIMCO LAKE CITY FL, FOUND FLOOR PANEL ON RT SIDE AT BS 280 CORRODED. FABRICATED NEW PANEL AND INSTALLED IAW DC9 SRM 51-21-0, 51-30-1.