What was found
DURING SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND CORROSION ON INNER FLANGE LT PANEL NR 2108A. CLEANED CORROSION ON INNER FLANGE. FABRICATED, TREATED, PRIMED AND INSTALLED STRIPS ON INNER FLANGE IAW DC9 SRM 51-10-3, 51-10-2, 51-10-4.