What was found
DURING SCHEDULED INSPECTION AT TIMCO, FOUND AFT PIT FWD LT BULKHEAD PANEL HAD SEVERAL SPOTS OF SURFACE CORROSION. MECHANICALLY CLEANED AREAS, FABRICATED NEW PANEL, LOCATED, DRILLED, DEBURRED, TREATED AND PRIMED IAW DC9 SRM 51-10-4, 51-10-3.