What was found
DURING SCHEDULED INSPECTION AT TIMCO, FOUND SEVERAL DENTS IN SKIN FROM BS 229-408 L18R AND L-26R. REMOVED AND REPLACED SKIN FROM BS 229-408 L18R-26R. INSTALLED NEW SPLICE SECTION IAW DC9 SRM 51-10-4, 51-10-3, 51-30-2, 51-30-5 AND TIMCO EO NR 99-1178.