What was found
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, UPON INSTALLATION FOUND CABIN FLOORBOARD NR 97 WEAK. FABRICATED A REPLACEMENT FLOORBOARD PANEL IAW DC9 SRM 53-21-0, DOUGLASS DRAWING NR 9915532 AND TIMCO RES NR 07642.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, UPON INSTALLATION FOUND CABIN FLOORBOARD NR 97 WEAK. FABRICATED A REPLACEMENT FLOORBOARD PANEL IAW DC9 SRM 53-21-0, DOUGLASS DRAWING NR 9915532 AND TIMCO RES NR 07642.