What was found
DURING SCHEDULED INSPECTION AT TIMCO LAKE CITY FLORIDA, FOUND CABIN FLOOR PANEL AT BS 200-237 CORRODED. FABRICATED AND INSTALLED NEW FLOOR PANEL IAW DC9 SRM 51-10-2, 51-30-3, 53-21-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED INSPECTION AT TIMCO LAKE CITY FLORIDA, FOUND CABIN FLOOR PANEL AT BS 200-237 CORRODED. FABRICATED AND INSTALLED NEW FLOOR PANEL IAW DC9 SRM 51-10-2, 51-30-3, 53-21-0.