What was found
DURING SCHEDULED INSPECTION AT TIMCO LAKE CITY FLORIDA, FOUND RT CUSP WEB CORRODED AT BS 945-965. REMOVED CUSP WEB. FABRICATED, ALODINED, PRIMED AND INSTALLED REPAIR SECTIONS OF WEB IAW DC9 SRM 53-05 FIG 97 AND MM 53-20-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED INSPECTION AT TIMCO LAKE CITY FLORIDA, FOUND RT CUSP WEB CORRODED AT BS 945-965. REMOVED CUSP WEB. FABRICATED, ALODINED, PRIMED AND INSTALLED REPAIR SECTIONS OF WEB IAW DC9 SRM 53-05 FIG 97 AND MM 53-20-1.