What was found
DURING SCHEDULED INSPECTION AT TIMCO LAKE CITY FLORIDA, FOUND AFT PIT LONGERON 30 CORRODED AT BS 870-965. CUT LONGERON FROM BS 870-955. REMOVED SHEAR TIES, FLOOR SUPPORT AND CUT FRAME AT BS 917. REMOVED LONGERON, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED NEW LONGERON. INSTALLED SHEAR TIES AND FLOOR SUPPORT. FABRICATED FRAME REPAIR, TREATED, PRIMED AND INSTALLED FRAME REPAIR IAW DC9 SRM 53-01 FIG1, 51-30-2, 51-10-4, 51-10-2, 51-30-2, 53-03 FIG 2A.