What was found
DURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND AFT VENTRAL STAIRS 5TH STEP FROM TOP. VERTICAL RISER ON STEP CORRODED. REMOVED AND REPLACED STEP IAW DC9 SRM 51-30-1, 52-01 FIGURE 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND AFT VENTRAL STAIRS 5TH STEP FROM TOP. VERTICAL RISER ON STEP CORRODED. REMOVED AND REPLACED STEP IAW DC9 SRM 51-30-1, 52-01 FIGURE 1.