What was found
DURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND FLOOR SUPPORT AT BS 161 - 198 AND LBL 44 CORRODED. FABRICATED AND INSTALLED REPAIR SUPPORT IAW DC9 SRM 51-10-3, 51-10-2, 51-10-4, 51-10-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND FLOOR SUPPORT AT BS 161 - 198 AND LBL 44 CORRODED. FABRICATED AND INSTALLED REPAIR SUPPORT IAW DC9 SRM 51-10-3, 51-10-2, 51-10-4, 51-10-5.