What was found
DURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND CABIN FLOOR SUPPORT AT BS 200 LBL 44 - 56 CORRODED. REMOVED FLOOR SUPPORT, FABRICATED, REPAIRED AND INSTALLED REPAIR SUPPORT IAW DC9 SRM 51-30-2, 51-10-2, 51-10-3, 51-10-4, 51-30-5.