What was found
DURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND CABIN FLOOR SUPPORT AT BS 200 LBL 1 - 20 CORRODED. REMOVED FLOOR SUPPORT, FABRICATED, REPAIRED AND INSTALLED REPAIR SUPPORT IAW DC9 SRM 51-10-2, 51-10-3, 51-10-4, 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND CABIN FLOOR SUPPORT AT BS 200 LBL 1 - 20 CORRODED. REMOVED FLOOR SUPPORT, FABRICATED, REPAIRED AND INSTALLED REPAIR SUPPORT IAW DC9 SRM 51-10-2, 51-10-3, 51-10-4, 51-30-5.