What was found
DURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND THE SKIN PANEL AT BS 332 - 362 L18R TO L26R CORRODED. A CLASS II TEMP REPAIR INSTALLED IN THE AREA. REMOVED SKIN, FABRICATED AND INSTALLED SKIN REPAIR IAW EO 99-123-9.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND THE SKIN PANEL AT BS 332 - 362 L18R TO L26R CORRODED. A CLASS II TEMP REPAIR INSTALLED IN THE AREA. REMOVED SKIN, FABRICATED AND INSTALLED SKIN REPAIR IAW EO 99-123-9.