What was found
FOUND DENT AT LEFT HAND BS 503-516, L-23L, FOUND TO BE 13.5 LONG EXCEEDS LIMITS OF DC9 SRM 53-04 FIGURE 38 TABLE C COND 1B PAR 3. REPAIRED, FABRICATED AND INSTALLED DOUBLER AT BS 503-516, L-23L IAW DC9 SRM 53-04 FIGURE 12B, 51-10-3, 51-30-2 AND TIMCO EO NR 99-1193 REV IR DATED 20 JULY 99 AND APPROVED BY DC9 SRM 53-01 FIGURE 12B SHEET 2.