What was found
FOUND FLOORBEAM UPPER ATTACH ANGLE HAD EXFOLIATION CORROSION AT BS 980 RBL 35-RBL 49. CUT OUT CORROSION, FABRICATED AND INSTALLED REPAIR IAW DC9 SRM 53-05 FIGURE 20A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOORBEAM UPPER ATTACH ANGLE HAD EXFOLIATION CORROSION AT BS 980 RBL 35-RBL 49. CUT OUT CORROSION, FABRICATED AND INSTALLED REPAIR IAW DC9 SRM 53-05 FIGURE 20A.