What was found
FOUND FLOORBEAM CHAFED AT BS 915. BLENDED AND FABRICATED REPAIR ANGLE AND FILLERS, TREATED, PRIMED, INSTALLED REPAIR IAW DC9 SRM 53-01 FIGURE 1, 51-30-1, 53-05 FIGURE 20A, 51-10-3, 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOORBEAM CHAFED AT BS 915. BLENDED AND FABRICATED REPAIR ANGLE AND FILLERS, TREATED, PRIMED, INSTALLED REPAIR IAW DC9 SRM 53-01 FIGURE 1, 51-30-1, 53-05 FIGURE 20A, 51-10-3, 51-30-5.