What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CRACK IN SKIN AT BS 614 LONGERON 2R. REMOVED CRACK AND INSTALLED DOUBLER IAW DC9 SRM 53-04 FIG 38, 51-10-04, AND 51-10-03.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CRACK IN SKIN AT BS 614 LONGERON 2R. REMOVED CRACK AND INSTALLED DOUBLER IAW DC9 SRM 53-04 FIG 38, 51-10-04, AND 51-10-03.