What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND HOLE DRILLED IN THE E & E COMPARTMENT BETWEEN BS 160 AND 180 LONGERON 27R. FABRICATED AND INSTALLED REPAIR IAW DC9 SRM 51-30-02, 53-02 FIG 18, 51-10-04, 51-10-03, AND 51-30-05.