What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND ANGLE STIFFENER CORRODED AT BS 699. REMOVED AND REPLACED STIFFENER IAW DC9 SRM 51-10-04 AND 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.