What was found
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CORROSION ON CUSP WEB TO BE OUT OF LIMITS AT BS 579 LONGERON 18R. FABRICATED AND INSTALLED WEB REPAIR IAW DC9 SRM 53-01 FIG 2, 51-10-04, 51-10-03, AND 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CORROSION ON CUSP WEB TO BE OUT OF LIMITS AT BS 579 LONGERON 18R. FABRICATED AND INSTALLED WEB REPAIR IAW DC9 SRM 53-01 FIG 2, 51-10-04, 51-10-03, AND 51-30-02.